01273 526 805 52 Bristol Gardens, Brighton, East Sussex, BN2 5JR
Menu
Construction Line Gold SMAS Worksafe Federation of Master Builders

Brickwork & Blockwork: The Differences That Matter On Site

Click Here To Enlarge This Photo Of Brickwork & Blockwork: The Differences That Matter On Site

On most commercial and residential projects of any scale, brickwork and blockwork will both feature in the specification.

Whilst experienced site managers and developers are well versed in working with both, the decisions around where each material is specified, how they interact within the wall structure and where the cost and programme implications lie are worth examining in detail, particularly as build specifications become increasingly performance-driven.

Where Each Material Belongs In The Build

The distinction between brickwork and blockwork on a modern project is rarely about capability and almost always about application.

Facing brickwork earns its place on external elevations where the masonry is doing two jobs simultaneously: contributing to the structural or enclosure function of the wall whilst also delivering the aesthetic that defines the building's character and marketability.

Blockwork, whether dense aggregate or lightweight aerated, is the workhorse of the inner leaf, internal partitions, party walls and substructure, where speed, cost efficiency and structural or thermal performance take precedence over appearance.

Getting this allocation right at the specification stage avoids the costly errors that arise when materials are substituted on site or when the interface between the two is not properly detailed.

Cavity Wall Performance & The Interface Between The Two Leaves

Thermal Continuity

The shift towards tighter Part L compliance on new residential and commercial projects has made the thermal performance of the inner leaf a more significant design consideration than it was a decade ago.

Lightweight aerated blockwork (whether Aircrete or Thermalite) consistently outperforms dense aggregate block on U-value calculations, and the choice of block specification in the inner leaf can have a meaningful impact on whether a wall construction achieves the target U-value without requiring additional insulation thickness in the cavity.

On projects where floor-to-ceiling heights, structural zone depths or planning constraints are tight, squeezing additional performance out of the block specification rather than increasing the cavity width is often a more practical route to compliance.

Differential Movement

One of the more technically demanding aspects of cavity wall construction is managing the differential movement between the outer leaf of brickwork and the inner leaf of blockwork.

The two materials have different coefficients of thermal and moisture movement, and a wall construction that does not adequately accommodate this through correctly positioned and detailed movement joints will develop cracking over time, regardless of the quality of the workmanship.

Movement joint spacing in facing brickwork is well established in BS 5628 and the guidance from brick manufacturers, but on projects with complex elevations, multiple material interfaces or unusual thermal exposure, getting the joint layout right requires careful thought at the design stage rather than a site-level decision during the build.

Structural Blockwork: Specification & Programme Considerations

Dense vs Lightweight In Load-Bearing Applications

Below ground and in load-bearing internal walls, the choice between dense aggregate blockwork and lightweight alternatives requires a structural engineer's input rather than a default to whichever product is most readily available.

Dense aggregate block offers higher compressive strength and better resistance to ground moisture in substructure applications, but its weight and the reduced laying speed it produces compared to lightweight block have programme and cost implications that should be factored into the tender at the outset.

Acoustic Performance In Party Walls

On residential developments and mixed-use schemes, the acoustic performance of party walls is a compliance requirement under Part E of the Building Regulations, and the block specification in these walls is a direct determinant of whether the construction achieves the required airborne and impact sound insulation values.

Dense aggregate blockwork is frequently specified in party wall constructions for this reason, and substituting a lightweight alternative without reassessing the acoustic performance of the complete wall construction is a common source of pre-completion failures on residential schemes.

Cost & Programme: Where The Real Decisions Lie

The cost differential between brickwork and blockwork on a per-square-metre basis is well understood, but the programme implications of how the two trades interact on site are sometimes less carefully managed.

The sequencing of brickwork and blockwork in a cavity wall construction, the management of wall tie installation and the co-ordination of cavity insulation installation between the two leaves all require clear planning to avoid the delays and defects that arise when these activities are poorly sequenced.

On large multi-plot residential developments, the efficiency with which the bricklaying subcontractor manages the interaction between the two leaves across multiple plots simultaneously is one of the more significant variables in programme performance.

Back To List